FM4001 - Provides FM4000en 64 zones to grade 2x standard

4040

The FM4001 expands the FM4000X to a maximum of 64 detection devices, 8 fire, 8 PA and 8 set / unset devices.

The 4001 expansion unit together with the FM4000X offers all the features listed for the FM4000X panel plus the following additional features

Features Include:
  • Individual indication for up to 88 wireless devices
  • 64 Alarm detection devices, each one of the eight zones on the 4000X is split to provide 8 separate device identifications
  • 8 P.A. devices
  • 8 Fire detection devices
  • 8 radio setting / unsetting devices
  • Time and date log of the last 500 events
  • Plain text descriptions of all radio devices may be entered to a maximum of 16 characters. – User can adjust the time and date, this will be recorded in the log
  • User can examine the log, the log will record user access
  • User can change the detection zone text descriptions
  • Engineer can set the time and date
  • Engineer can display or print the log
  • Engineer can display or print all the panel programmable parameters
  • Engineer can use the log for walk testing
  • Engineer can enter or change the detection zone descriptions
  • A flying lead is provided with the 4001, which simply plugs into the 4000X
  • LCD display is designed to be mounted at eye level with the 4000X mounted below
  • 3 Digit device numbers when programming allow easy addition or removal of individual devices
  • LCD display is illuminated when a correct PIN is keyed in allowing the display to be read easily
  • Dimensions of FM4000X & FM4001 together 270mm wide x 310mm high x 80mm deep